Nuclide reference

Te-127m — Tellurium-127m

Te-127m की half-life 109 d है। मुख्य decay mode: isomeric transition → Te-127 (97.6%)।

Identification

तत्व
Tellurium (Te)
Atomic number Z
52
Mass number A
127
State
Radioactive

Key quantities

Half-life
109 d
विशिष्ट गतिविधि
3.49e+14 Bq/g
Gamma constant Γ
—
परिवहन के लिए A1 / A2 (SSR-6)
20 TBq / 0.5 TBq
D-value (НП-067-24)
3 TBq

Decay modes

  • isomeric transition → Te-127 — 97.6 %
  • β⁻ decay → I-127 — 2.4 %

Main gamma lines

Energy, keVYield, %
27.472 · X-ray line19.7
27.202 · X-ray line10.49
417.9 (Te-127)0.9697
57.630.5024
360.3 (Te-127)0.1319
88.260.08355
202.9 (Te-127)0.05682
215.1 (Te-127)0.03792
57.63 (Te-127)0.02909
658.90.01232

Includes daughter nuclides in equilibrium: Te-127 (yield per decay of Te-127m); the emitting nuclide is in brackets. Equilibrium is reached in about 2.7 d.

Alpha and beta particles

RadiationEnergy, keVYield, %
β⁻, E max728.622.376
702 (Te-127)96.76
284.07 (Te-127)1.166
499.14 (Te-127)0.02645

For β⁻ the endpoint (maximum) energy of the spectrum is given. ENDF/B-VIII.0.

Related calculators

Reference data vs computed valuesHalf-life, gamma lines and D-value are reference data (ENDF/B-VIII.0, НП-067-24).Gamma constant Γ 1 m पर H*(10) है, ICRP-107 spectra (NIST µ_en/ρ, ICRP-74 Table A.21) से गणना की गई, equilibrium में short-lived progeny सहित (जैसे Cs-137/Ba-137m, Ra-226 series); specific activity molar mass M ≈ mass number A का उपयोग करती है।K-series X-ray energies are from NIST SRD 128 (Deslattes et al., 2003): in ENDF/B-VIII.0 they are given to 1 % and shifted by up to 0.7 keV for heavy elements. L-series lines and all yields are ENDF/B-VIII.0.

Tellurium-127m (Te-127m) — reference data

What is in the card

This card gathers the key data of radionuclide Te-127m in one place: half-life, decay modes, main gamma lines, alpha and beta particle energies, gamma constant, specific activity and the D-value for source categorization. Decay and emission data are from ENDF/B-VIII.0; the D-value follows NP-067-24; the gamma constant is the ambient dose equivalent H*(10) at 1 m, computed from ICRP-107 spectra.

How to use the data

Half-life and specific activity let you recalculate the activity of a Te-127m source to the delivery or disposal date — use the decay calculator. Gamma lines with yields identify the nuclide from a spectrum and pick the line for gamma spectrometry; the gamma constant Γ gives the dose rate at a distance, while the D-value and A1/A2 set the source category and the package type for transport.