Nuclide reference

Pm-144 — Promethium-144

Pm-144 की half-life 363 d है। मुख्य decay mode: β⁺ decay / electron capture → Nd-144 (100%)।

Identification

तत्व
Promethium (Pm)
Atomic number Z
61
Mass number A
144
State
Radioactive

Key quantities

Half-life
363 d
विशिष्ट गतिविधि
9.243e+13 Bq/g
Gamma constant Γ
—
परिवहन के लिए A1 / A2 (SSR-6)
0.7 TBq / 0.7 TBq
D-value (НП-067-24)
0.04 TBq

Decay modes

  • β⁺ decay / electron capture → Nd-144 — 100 %

Main gamma lines

Energy, keVYield, %
696.4999.49
618.0198.5
476.7843.78
37.361 · X-ray line40.93
36.848 · X-ray line22.47
778.571.502
6940.5472
814.140.5472
582.40.189
301.70.1791

Lines of the bare nuclide (ENDF/B-VIII.0), without daughter ingrowth.

Related calculators

Reference data vs computed valuesHalf-life, gamma lines and D-value are reference data (ENDF/B-VIII.0, НП-067-24).Gamma constant Γ 1 m पर H*(10) है, ICRP-107 spectra (NIST µ_en/ρ, ICRP-74 Table A.21) से गणना की गई, equilibrium में short-lived progeny सहित (जैसे Cs-137/Ba-137m, Ra-226 series); specific activity molar mass M ≈ mass number A का उपयोग करती है।K-series X-ray energies are from NIST SRD 128 (Deslattes et al., 2003): in ENDF/B-VIII.0 they are given to 1 % and shifted by up to 0.7 keV for heavy elements. L-series lines and all yields are ENDF/B-VIII.0.

Promethium-144 (Pm-144) — reference data

What is in the card

This card gathers the key data of radionuclide Pm-144 in one place: half-life, decay modes, main gamma lines, alpha and beta particle energies, gamma constant, specific activity and the D-value for source categorization. Decay and emission data are from ENDF/B-VIII.0; the D-value follows NP-067-24; the gamma constant is the ambient dose equivalent H*(10) at 1 m, computed from ICRP-107 spectra.

How to use the data

Half-life and specific activity let you recalculate the activity of a Pm-144 source to the delivery or disposal date — use the decay calculator. Gamma lines with yields identify the nuclide from a spectrum and pick the line for gamma spectrometry; the gamma constant Γ gives the dose rate at a distance, while the D-value and A1/A2 set the source category and the package type for transport.