Nuclide reference

Te-129m — Tellurium-129m

The half-life of Te-129m is 33.6 d. Main decay mode: isomeric transition to Te-129 (63%).

Identification

Element
Tellurium (Te)
Atomic number Z
52
Mass number A
129
State
Radioactive

Key quantities

Half-life
33.6 d
Specific activity
1.115e+15 Bq/g
Gamma constant Γ
—
A1 / A2 for transport (SSR-6, НП-053-16)
0.8 TBq / 0.4 TBq
D-value (НП-067-24)
1 TBq

Decay modes

  • isomeric transition → Te-129 — 63 %
  • β⁻ decay → I-129 — 37 %

Main gamma lines

Energy, keVYield, %
27.472 · X-ray line15.01
27.81 (Te-129)10.3
27.202 · X-ray line8.017
459.6 (Te-129)4.858
695.883.071
487.39 (Te-129)0.8939
729.570.7167
278.43 (Te-129)0.3575
1,083.85 (Te-129)0.3109
250.62 (Te-129)0.2414

Includes daughter nuclides in equilibrium: Te-129 (yield per decay of Te-129m); the emitting nuclide is in brackets. Equilibrium is reached in about 8.1 h.

Alpha and beta particles

RadiationEnergy, keVYield, %
β⁻, E max1,608.533.09
912.613.117
1,475.2 (Te-129)56.15
1,015.7 (Te-129)5.867

For β⁻ the endpoint (maximum) energy of the spectrum is given. ENDF/B-VIII.0.

Related calculators

Reference data vs computed valuesHalf-life, gamma lines and D-value are reference data (ENDF/B-VIII.0, НП-067-24).Gamma constant Γ is H*(10) at 1 m computed from ICRP-107 spectra (NIST µ_en/ρ, ICRP-74 Table A.21) including short-lived progeny in equilibrium (e.g. Cs-137/Ba-137m, Ra-226 series); specific activity uses molar mass M ≈ mass number A.K-series X-ray energies are from NIST SRD 128 (Deslattes et al., 2003): in ENDF/B-VIII.0 they are given to 1 % and shifted by up to 0.7 keV for heavy elements. L-series lines and all yields are ENDF/B-VIII.0.

Tellurium-129m (Te-129m) — reference data

What is in the card

This card gathers the key data of radionuclide Te-129m in one place: half-life, decay modes, main gamma lines, alpha and beta particle energies, gamma constant, specific activity and the D-value for source categorization. Decay and emission data are from ENDF/B-VIII.0; the D-value follows NP-067-24; the gamma constant is the ambient dose equivalent H*(10) at 1 m, computed from ICRP-107 spectra.

How to use the data

Half-life and specific activity let you recalculate the activity of a Te-129m source to the delivery or disposal date — use the decay calculator. Gamma lines with yields identify the nuclide from a spectrum and pick the line for gamma spectrometry; the gamma constant Γ gives the dose rate at a distance, while the D-value and A1/A2 set the source category and the package type for transport.