Nuclide reference

Na-22 — Sodium-22

The half-life of Na-22 is 2.6027 years. Main decay mode: β⁺ decay / electron capture to Ne-22 (100%).

Identification

Element
Sodium (Na)
Atomic number Z
11
Mass number A
22
State
Radioactive

Key quantities

Half-life
2.6027 years
Specific activity
2.31e+14 Bq/g
Gamma constant Γ (H*(10))
0.3324 µSv·m²/(MBq·h)
Dose rate, 1 GBq at 1 m
≈ 332 µSv/h
A1 / A2 for transport (SSR-6, НП-053-16)
0.5 TBq / 0.5 TBq
D-value (НП-067-24)
0.03 TBq

Decay modes

  • β⁺ decay / electron capture → Ne-22 — 100 %

Main gamma lines

Energy, keVYield, %
510.999 · annihilation 511 keV179.9
1,274.5499.94

Lines of the bare nuclide (ENDF/B-VIII.0), without daughter ingrowth.

Alpha and beta particles

RadiationEnergy, keVYield, %
β⁺, E max546.4589.89
1,8210.055

For β⁺ the endpoint (maximum) energy of the spectrum is given. ENDF/B-VIII.0.

Related calculators

Reference data vs computed valuesHalf-life, gamma lines and D-value are reference data (ENDF/B-VIII.0, НП-067-24).Gamma constant Γ is H*(10) at 1 m computed from ICRP-107 spectra (NIST µ_en/ρ, ICRP-74 Table A.21) including short-lived progeny in equilibrium (e.g. Cs-137/Ba-137m, Ra-226 series); specific activity uses molar mass M ≈ mass number A.Dose rate example: point source, no shielding or scatter, Ḣ = Γ·A/r².

Sodium-22 (Na-22) — reference data

What is in the card

This card gathers the key data of radionuclide Na-22 in one place: half-life, decay modes, main gamma lines, alpha and beta particle energies, gamma constant, specific activity and the D-value for source categorization. Decay and emission data are from ENDF/B-VIII.0; the D-value follows NP-067-24; the gamma constant is the ambient dose equivalent H*(10) at 1 m, computed from ICRP-107 spectra.

How to use the data

Half-life and specific activity let you recalculate the activity of a Na-22 source to the delivery or disposal date — use the decay calculator. Gamma lines with yields identify the nuclide from a spectrum and pick the line for gamma spectrometry; the gamma constant Γ gives the dose rate at a distance, while the D-value and A1/A2 set the source category and the package type for transport.