Radiological Units Conversions

Dose unit converter

1 Sv = 1,000 mSv = 1,000,000 µSv = 100 rem · 1 Gy = 100 rad · gamma in soft tissue: 1 R ≈ 9.6 mSv

From
Equivalent dose
Absorbed dose
Exposure dose
mSv
1 mSv = 100 mrem
To
Equivalent dose
Absorbed dose
Exposure dose
100mrem
1 mrem = 0.01 mSv

Cross-family dose conversions (Sv↔Gy↔R) are estimates that depend on radiation type and medium (w_R, µ_en/ρ); conversions within one family are exact. Verify against accredited methods for official decisions.

Dose units: what they measure and how they relate

UnitQuantityValueWhere you see it
Sv (sievert)effective and equivalent doseSI unitstandards, annual doses
mSv (millisievert)same0.001 Svdose limits, medical procedures
µSv (microsievert)same10⁻⁶ Svdosimeter readings in µSv/h, background radiation
nSv (nanosievert)same10⁻⁹ Svbackground dose rate in nSv/h at monitoring stations
remequivalent dose, non-SI0.01 Svolder documents, USA
Gy (gray)absorbed doseSI unitradiotherapy, material irradiation
mGy (milligray)same0.001 GyX-ray and CT doses
radabsorbed dose, non-SI0.01 Gyolder documents, USA
R (roentgen)exposure, non-SI2.58·10⁻⁴ C/kgolder survey meters and documents
µR (microroentgen)same10⁻⁶ Rconsumer dosimeters, µR/h

Radiation Dose Unit Converter

Three dosimetric quantities

The calculator converts dose units within three distinct dosimetric quantities. Equivalent dose is measured in sievert (Sv, mSv, µSv) and rem (rem, mrem): 1 Sv = 100 rem. Absorbed dose is measured in gray (Gy, mGy, µGy) and rad (rad, mrad): 1 Gy = 100 rad. Exposure dose is expressed in roentgen (R, mR).

Cross-conversion between families

Within one family the conversion is exact, by fixed factors. Between families (gray → sievert, roentgen → sievert or gray) it works only with explicit context: the radiation type sets the weighting factor w_R in Sv = Gy × w_R, and for roentgen the medium (air, tissue, water) sets the step Gy = R × medium factor. You set these assumptions yourself — the calculator shows the coefficient, the formula and the standard (NRB-99/2009 or ICRP-103), and marks the cross result as an estimate.

Equivalent vs effective dose

Absorbed, equivalent and exposure dose are kept strictly distinct here. A cross conversion returns equivalent dose H = D · w_R, not effective dose, which needs organ tissue weighting factors. The value of w_R depends on the standard — for protons and neutrons NRB-99/2009 (legal in Russia) and ICRP-103 diverge, so the standard is switched in the calculator.

Frequently asked questions

How many roentgens are in a sievert?

For gamma radiation in soft tissue 1 Sv ≈ 104 R and 1 R ≈ 0.0096 Sv; in air 1 R = 0.00876 Gy. The exact factor depends on the medium and radiation type — the converter lets you choose both explicitly.

What is the difference between sievert, gray and roentgen?

The gray is absorbed dose (J/kg), the sievert is equivalent or effective dose weighted by the radiation weighting factor, and the roentgen is exposure in air for photons. For photons and beta w_R = 1, for alpha it is 20.

How do I convert rem to sievert?

1 rem = 0.01 Sv (1 Sv = 100 rem) and 1 rad = 0.01 Gy. These are exact relations between the older non-SI units and the modern SI units.